Reliable Perkins Diesel Generators for Standby Emergency Power
9~400KVA
| 50HZ | 1500 rmp/400v 3P 4W/50HZ/0.8PF | ENGINE | |||||||
| PRP | STP | Model | Fuel Cons. (L/ph) |
Prime (KW) |
N Cyl. | Cyl.Liters | |||
| KVA | KW | KVA | KW | ||||||
| JSP-9T5※ | 9.0 | 7.2 | 10.0 | 8.0 | 403A-11G1☆ | 2.6 | 8.6 | 3 | 1.1 |
| JSP-9T5 | 9.0 | 7.2 | 10.0 | 8.0 | 403D-11G☆ | 3.2 | 10.7 | 3 | 1.1 |
| JSP-13T5※ | 13.0 | 10.4 | 14.5 | 11.6 | 403A-15G1☆ | 3.7 | 12.2 | 3 | 1.5 |
| JSP-13T5※ | 13.0 | 10.4 | 16.1 | 12.9 | 403D-15G☆ | 3.7 | 12.2 | 3 | 1.5 |
| JSP-15T5※ | 14.8 | 11.8 | 16.1 | 12.9 | 403A-15G2☆ | 4.1 | 13.6 | 3 | 1.5 |
| JSP-20T5※ | 20.0 | 16 | 22.1 | 17.7 | 404A-22G1☆ | 5.3 | 18.7 | 4 | 2.2 |
| JSP-20T5 | 20.0 | 16 | 22.1 | 17.7 | 404D-22G☆ | 5.3 | 18.7 | 4 | 2.2 |
| JSP-27.4T5※ | 27.4 | 21.9 | 32.9 | 26.3 | 404D-22TG☆ | 7.1 | 25.2 | 4 | 2.2 |
| JSP-30T5※ | 30.0 | 24 | 32.5 | 26.0 | 1103A-33G | 7.1 | 28.2 | 3 | 3.3 |
| JSP-45T5※ | 45.0 | 36 | 50.0 | 40.0 | 1103A-33TG1 | 10.7 | 42.2 | 3 | 3.3 |
| JSP-60T5※ | 60.0 | 48 | 66.3 | 53.0 | 1103A-33TG2 | 13.9 | 59.3 | 3 | 3.3 |
| JSP-65T5※ | 65.0 | 52 | 71.3 | 57.0 | 1104A-44TG1☆ | 14.8 | 59.6 | 4 | 4.4 |
| JSP-80T5※ | 80.0 | 64 | 87.5 | 70.0 | 1104A-44TG2☆ | 18.7 | 73.4 | 4 | 4.4 |
| JSP-80T5※ | 80.0 | 64 | 88.8 | 71.0 | 1104C-44TAG1☆ | 18.6 | 75 | 4 | 4.4 |
| JSP-100T5※ | 100.0 | 80 | 112.5 | 90.0 | 1104C-44TAG2☆ | 22.6 | 93.6 | 4 | 4.4 |
| JSP-135T5 | 135.0 | 108 | 150.0 | 120.0 | 1106A-70TG1☆ | 30.2 | 123.7 | 6 | 7.0 |
| JSP-150T5 | 150.0 | 120 | 165.0 | 132.0 | 1106A-70TAG2☆ | 34.6 | 135 | 6 | 7.0 |
| JSP-180T5 | 180.0 | 144 | 200.0 | 160.0 | 1106A-70TAG3☆ | 45.0 | 163.9 | 6 | 7.0 |
| JSP-200T5 | 200.0 | 160 | 220.0 | 176.0 | 1106A-70TAG4☆ | 49.4 | 178.9 | 6 | 7.0 |
| JSP-200T5 | 200.0 | 160 | 220.0 | 176.0 | 1206A-E70TTAG1 | 45.8 | 176.8 | 6 | 7.0 |
| JSP-200T5 | 200.0 | 160 | 220.0 | 176.0 | 1206D-E70TTAG1 | 45.8 | 1.76.8 | 6 | 7.0 |
| JSP-225T5 | 225.0 | 180 | 250.0 | 200.0 | 1206A-E70TTAG2 | 51.0 | 195.2 | 6 | 7.0 |
| JSP-225T5 | 225.0 | 180 | 250.0 | 200.0 | 1206D-E70TTAG2 | 51.0 | 195.2 | 6 | 7.0 |
| JSP-231 5※ | 231.3 | 185 | 257.5 | 206.0 | 1506A-E88TAG2 | 51.0 | 204 | 6 | 8.8 |
| JSP-250T5※ | 250.0 | 200 | 282.5 | 226.0 | 1506A-E88TAG3 | 56.0 | 222 | 6 | 8.8 |
| JSP-250T5 | 250.0 | 200 | 275.0 | 220.0 | 1206A-E70TTAG3 | 56.9 | 217 | 6 | 7.0 |
| JSP-250T5 | 250.0 | 200 | 275.0 | 220.0 | 1206D-E70TTAG3 | 56.9 | 217 | 6 | 7.0 |
| JSP-307.5T5※ | 307.5 | 246 | 337.5 | 270.0 | 1506A-E88TAG5 | 65.0 | 267 | 6 | 8.8 |
| JSP-350T5 | 350.0 | 280 | 400.0 | 320.0 | 2206C-E13TAG2 | 75 | 305 | 6 | 12.5 |
| JSP-400T5 | 400.0 | 320 | 450.0 | 360.0 | 2206C-E13TAG3 | 85 | 349 | 6 | 12.5 |
400~2250KVA
| 50HZ | 1500 rmp/400v 3P 4W/50HZ/0.8PF | ENGINE | |||||||
| PRP | STP | Model | Fuel Cons. (L/ph) |
Prime (KW) |
N Cyl. | Cyl.Liters | |||
| KVA | KW | KVA | KW | ||||||
| JSP-455T5 | 455.0 | 364 | 500.0 | 400.0 | 2506C-E15TAG1 | 99 | 396 | 6 | 15.2 |
| JSP-500T5※ | 500.0 | 400 | 550.0 | 440.0 | 2506C-E15TAG2 | 106 | 435 | 6 | 15.2 |
| JSP-591T5※ | 591.3 | 473 | 650.0 | 520.0 | 2806C-E18TAG1A | 129 | 514 | 6 | 18.1 |
| JSP-650T5 | 650.0 | 520 | 700.0 | 560.0 | 2806A-E18TAG2 | 132 | 565 | 6 | 18.1 |
| JSP-713T5※ | 712.5 | 570 | 783.8 | 627.0 | 2806A-E18TTAG4 | 150 | 600 | 6 | 18.1 |
| JSP-773T5※ | 771.3 | 617 | 847.5 | 678.0 | 2806A-E18TTAG5 | 162 | 646 | 6 | 18.1 |
| JSP-746T5※ | 746.3 | 597 | 820.0 | 656.0 | 4006-23TAG2A | 163 | 658 | 6 | 22.9 |
| JSP-800T5 | 800.0 | 640 | 897.5 | 718.0 | 4006-23TAG3A | 175 | 705 | 6 | 22.9 |
| JSP-910T5 | 910.0 | 728 | 1002.5 | 802.0 | 4008TAG1A | 195 | 805 | 8 | 30.6 |
| JSP-1023T5※ | 1022.5 | 818 | 1125.0 | 900.0 | 4008TAG2 | 213 | 851 | 8 | 30.6 |
| JSP-1023T5 | 1022.5 | 818 | 1125.0 | 900.0 | 4008TAG2A | 215 | 861 | 8 | 30.6 |
| JSP-1125T5 | 1125.0 | 900 | 1250.0 | 1000.0 | 4008-30TAG3 | 244 | 947 | 8 | 30.6 |
| JSP-1250T5 | 1250.0 | 1000 | 1375.0 | 1100.0 | 4012-46TAGOA | 255 | 1053 | 12 | 45.8 |
| JSP-1250T5※ | 1250.0 | 1000 | 1375.0 | 1100.0 | 4012-46TWG2A | 258 | 1106 | 12 | 45.8 |
| JSP-1375T5 | 1375.0 | 1100 | 1500.0 | 1200.0 | 4012-46TWG3A | 280 | 1200 | 12 | 45.8 |
| JSP-1500T5※ | 1500.0 | 1200 | 1650.0 | 1320.0 | 4012-46TAG2A | 328 | 1212 | 12 | 45.8 |
| JSP-1688T5 | 1687.5 | 1350 | 1875.0 | 1500.0 | 4012-46TAG3A | 381 | 1500 | 12 | 45.8 |
| JSP-1850T5 | 1850.0 | 1480 | 2000.0 | 1600.0 | 4016TAG1A | 383 | 1588 | 16 | 61.1 |
| JSP2000T5 | 2000.0 | 1600 | 2250.0 | 1800.0 | 4016-61TRG2 | 421 | 1744 | 16 | 61.1 |
| JSP-2000T5 | 2000.0 | 1600 | 2250.0 | 1800.0 | 4016TAG2A | 434 | 1766 | 16 | 61.1 |
| JSP-2250T5 | 2250.0 | 1800 | 2500.0 | 2000.0 | 4016-61TRG3 | 473 | 1975 | 16 | 61.1 |
400~2250KVA
| 60HZ | 1800 rmp/480v 3P 4W/60HZ/0.8PF | ENGINE | |||||||
| PRP | STP | Model |
Fuel Cons. (L/ph) |
Prime (KW) | N Cyl. | Cyl,Liters | |||
| KVA | KW | KVA | KW | ||||||
| JSP-11T6※ | 11.3 | 9 | 12.4 | 9.9 | 403A-11G1☆ | 3.2 | 10.7 | 3 | 1.1 |
| JSP-11T6 | 11.3 | 9 | 12.4 | 9.9 | 403D-11G☆ | 3.2 | 10.7 | 3 | 1.1 |
| JSP-16T6※ | 15.9 | 12.7 | 17.5 | 14.0 | 403A-15G1☆ | 4.3 | 14.7 | 3 | 1.5 |
| JSP-16T6※ | 15.9 | 12.7 | 17.5 | 14.0 | 403D-15G☆ | 4.3 | 14.7 | 3 | 1.5 |
| JSP-18T6※ | 17.5 | 14 | 19.5 | 15.6 | 403A-15G2☆ | 5.7 | 16 | 3 | 1.5 |
| JSP-24T6※ | 24.0 | 19.2 | 26.6 | 21.3 | 404A-22G1☆ | 6.2 | 22 | 4 | 2.2 |
10~1800KVA
| 60HZ | 1800 rmp/480v 3P 4W /60HZ/0.8PF | ENGINE | |||||||
| PRP | STP | Model | Fuel Cons. (L/ph) |
Prime (KW) |
N Cyl. | Cyl, Liters | |||
| KVA | KW | KVA | KW | ||||||
| JSP-11T6※ | 11.3 | 9 | 12.4 | 9.9 | 403A-11G1☆ | 3.2 | 10.7 | 3 | 1.1 |
| JSP-11T6 | 11.3 | 9 | 12.4 | 9.9 | 403D-11G☆ | 3.2 | 10.7 | 3 | 1.1 |
| JSP-16T6※ | 15.9 | 12.7 | 17.5 | 14.0 | 403A-15G1☆ | 4.3 | 14.7 | 3 | 1.5 |
| JSP-16T6※ | 15.9 | 12.7 | 17.5 | 14.0 | 403D-15G☆ | 4.3 | 14.7 | 3 | 1.5 |
| JSP-18T6※ | 17.5 | 14 | 19.5 | 15.6 | 403A-15G2☆ | 5.7 | 16 | 3 | 1.5 |
| JSP-24T6※ | 24.0 | 19.2 | 26.6 | 21.3 | 404A-22G1☆ | 6.2 | 22 | 4 | 2.2 |
| JSP-24T6 | 24.0 | 19.2 | 26.6 | 21.3 | 404D-22G☆ | 6.2 | 22 | 4 | 2.2 |
| JSP-30T6※ | 30.0 | 24 | 36.3 | 29.0 | 404D-22TG☆ | 8.3 | 30.3 | 4 | 2.2 |
| JSP-35T6※ | 35.0 | 28 | 38.8 | 31.0 | 1103A-33G | 8.6 | 32.2 | 4 | 3.3 |
| JSP-54T6※ | 53.8 | 43 | 58.8 | 47.0 | 1103A-33TG1 | 12.9 | 48.9 | 4 | 3.3 |
| JSP-69T6※ | 68.8 | 55 | 75.0 | 60.0 | 1103A-33TG2 | 16.6 | 61.2 | 4 | 3.3 |
| JSP-75T6※ | 75.0 | 60 | 83.8 | 67.0 | 1104A-44TG1☆ | 16.6 | 64.0 | 4 | 4.4 |
| JSP-90T6※ | 90.0 | 72 | 100 | 80 | 1104C-44TAG1☆ | 19.0 | 66.2 | 4 | 4.4 |
| JSP-90T6※ | 90.0 | 72 | 100 | 80 | 1104A-44TG2☆ | 23.7 | 88 | 4 | 4.4 |
| JSP-113T6※ | 113 | 90 | 126 | 101 | 1104C-44TAG2☆ | 27.7 | 106 | 4 | 4.4 |
| JSP-153T6 | 152.5 | 122 | 168.8 | 135.0 | 1106A-70TG1☆ | 35.2 | 140.5 | 6 | 7.0 |
| JSP-169T6 | 168.8 | 135 | 187.5 | 150.0 | 1106A-70TAG2☆ | 38.2 | 155.0 | 6 | 7.0 |
| JSP-198T6 | 197.5 | 158 | 218.8 | 175.0 | 1106A-70TAG3☆ | N.A | 173.0 | 6 | 7.0 |
| JSP-225T6 | 225.0 | 180 | 250.0 | 200.0 | 1206A-E70TTAG1 | 54.5 | 201.6 | 6 | 7.0 |
| JSP-225T6 | 225.0 | 180 | 250.0 | 200.0 | 1206DE70TTAG1/G2/G3 | 54.4 | 201.6 | 6 | 7.0 |
| JSP-248T6※ | 247.5 | 198 | 272.5 | 218.0 | 1506A-E88TAG2 | 58.0 | 218.0 | 6 | 8.8 |
| JSP-290T6※ | 290.0 | 232 | 320.0 | 256.0 | 1506A-E88TAG3 | 58 | 218.0 | 6 | 8.8 |
| JSP-350T6※ | 350.0 | 280 | 390.0 | 312.0 | 1506AE88TAG5/G2/G3 | 82 | 306.0 | 6 | 8.8 |
| JSP-400T6 | 400.0 | 320 | 437.5 | 350.0 | 2206C-E13TAG2 | 84 | 373.0 | 6 | 12.5 |
| JSP-400T6 | 400.0 | 320 | 437.5 | 350.0 | 2206C-E13TAG3 | 84 | 373.0 | 6 | 12.5 |
| JSP-500T6 | 500.0 | 400 | 562.5 | 450.0 | 2506C-E15TAG1 | 100 | 435.0 | 6 | 15.0 |
| JSP-500T6※ | 500.0 | 400 | 562.5 | 450.0 | 2506C-E15TAG2 | 100.0 | 435.0 | 6 | 15.0 |
| JSP-625T6※ | 625.0 | 500 | 687.5 | 550.0 | 2806C-E18TAG1A | 130.0 | 543.0 | 6 | 18.1 |
| JSP-625T6 | 625.0 | 500 | 687.5 | 550.0 | 2806A-E18TAG2 | 127.0 | 543.0 | 6 | 18.1 |
| JSP-750T6 | 750 | 600 | 825 | 660 | 4006-23TAG2A | 176 | 676 | 6 | 22.9 |
| JSP-826T6※ | 826.3 | 661 | 908.8 | 727.0 | 2806A-E18TTAG4 | 179 | 693 | 6 | 18.1 |
| JSP-826T6※ | 826.3 | 661 | 908.8 | 727.0 | 2806A-E18TTAG5 | 179 | 693 | 6 | 18.1 |
| JSP-849T6 | 848.8 | 679 | 943.8 | 755.0 | 4006-23TAG3A | 189.6 | 759 | 6 | 22.9 |
| JSP-1000T6※ | 1000 | 800 | 1100 | 880 | 4008TAG2 | 224.0 | 898 | 8 | 30.6 |
| JSP-1250T6※ | 1250 | 1000 | 1375 | 1100 | 4012-46TWG2A | 266.0 | 1106 | 12 | 45.8 |
| JSP-1500T6※ | 1500 | 1200 | 1650 | 1320 | 4012-46TAG2A | 319.0 | 1332 | 12 | 45.8 |
| JSP-1688T6 | 1687.5 | 1350 | 1856.3 | 1485.0 | 4012-46TAG3A | 356 | 1440 | 12 | 45.8 |
JSSTPower Industrial Diesel Generator – Perkins Series
Unmatched Reliability. Engineered for Excellence. Powered by Legendary Perkins Technology.
Demanding industrial applications require a diesel generator that combines robust performance with proven engineering heritage.
The JSSTPower Perkins Series delivers exceptional power, efficiency, and durability for sectors such as manufacturing, construction, data centers, healthcare, and emergency backup systems.
Built with genuine Perkins engines—synonymous with superior craftsmanship and innovation—this generator series ensures optimized fuel efficiency, reduced maintenance, and unwavering reliability even in the most challenging environments. With a power range spanning 15kW to 2000kW and compatibility with both 50Hz and 60Hz frequencies, the Perkins Series is designed to meet global standards and adapt to diverse operational needs.
The JSSTPower Perkins Series delivers exceptional power, efficiency, and durability for sectors such as manufacturing, construction, data centers, healthcare, and emergency backup systems.
Built with genuine Perkins engines—synonymous with superior craftsmanship and innovation—this generator series ensures optimized fuel efficiency, reduced maintenance, and unwavering reliability even in the most challenging environments. With a power range spanning 15kW to 2000kW and compatibility with both 50Hz and 60Hz frequencies, the Perkins Series is designed to meet global standards and adapt to diverse operational needs.
Key Features
Wide Power Output: 9KVA to 22250KVA, ideal for small, medium, and large-scale industrial applications
Authentic Perkins Engines: Designed and manufactured to offer exceptional performance, longevity, and low total cost of ownership
Dual Frequency Support: Configurable for 50Hz and 60Hz applications to suit regional requirements
Mission-Critical Durability: Engineered for continuous operation in high-demand environments
Customization Options: Available as open or silent canopies, with optional remote monitoring, automatic transfer switches, and trailer mobility
Authentic Perkins Engines: Designed and manufactured to offer exceptional performance, longevity, and low total cost of ownership
Dual Frequency Support: Configurable for 50Hz and 60Hz applications to suit regional requirements
Mission-Critical Durability: Engineered for continuous operation in high-demand environments
Customization Options: Available as open or silent canopies, with optional remote monitoring, automatic transfer switches, and trailer mobility
✅ Dependable Power, Designed for Your Needs
Trust a generator brand known worldwide for precision engineering and relentless reliability.
👉 Request a customized quote—our specialists will help design the ideal power solution for your project.
📄 Download the JSSTPower Perkins Series brochure for detailed specifications and configuration options.
💬 Questions? Contact our sales team for expert advice and support.
JSSTPower – Powered by Perkins, Built for Industrial Mastery.
👉 Request a customized quote—our specialists will help design the ideal power solution for your project.
📄 Download the JSSTPower Perkins Series brochure for detailed specifications and configuration options.
💬 Questions? Contact our sales team for expert advice and support.
JSSTPower – Powered by Perkins, Built for Industrial Mastery.
![]() |
ATS Box The ATS detects power outages and automatically starts the generator—even when you’re away. Once mains power is restored, it seamlessly switches back automatically. |
![]() |
Generator Parallel System Connect multiple generators in parallel to flexibly adjust power output, enhancing supply stability and adapting to varying load demands. |
![]()
|
Jacket Heater and Oil Heater Engineered to maintain optimal performance and ensure reliable operation even in cold temperatures below 0℃. |
![]() |
Maintenance Parts Oil Filter / Fuel Filter / Air Filter |
![]()
|
External Fuel Tank & Large Base Fuel Tank – Extend your generator's runtime with a variety of fuel tank options in different litre capacities. |